Radiofrecuencia en casa: guía completa de dispositivos TriPollar y resultados

Radiofrequency at home: complete guide to devices and results

by Belén
Technology · Radiofrequency · Complete Guide

Radiofrequency at home: complete guide to devices and results

Radiofrequency has left the clinic. What for years was synonymous with medical aesthetic treatments reserved for a few, is today an accessible, clinically validated technology designed to integrate into the daily routine at home. But not all devices work the same way, and understanding the differences is the key to choosing well and seeing real results.

At SKINVITY we work with four radiofrequency devices developed by Pollogen and Lumenis, two of the world's leading references in medical aesthetic technology. This guide explains how each one works, what technology it incorporates, what clinical results validate its efficacy, and how to integrate them into your routine.

In this guide
  1. How radiofrequency works on the skin
  2. TriPollar Aura: facial radiofrequency with 6 frequencies and red LED
  3. TriPollar STOP Vx2: facial multi-RF with deep muscle activation
  4. TriPollar POSE Vx: body radiofrequency and muscle remodelling
  5. TriPollar Envig EDGE: fractional radiofrequency for skin renewal
  6. Comparison table of all four devices
  7. How to combine them with your routine
  8. Frequently asked questions

How radiofrequency works on the skin

Quick answer

Radiofrequency emits electromagnetic waves that penetrate the dermis and generate controlled heat. That heat triggers two responses: the immediate contraction of existing collagen fibres, visible from the first session as a flash effect, and the stimulation of fibroblasts to produce new collagen and elastin over the following weeks. Results are cumulative and consolidate with regular use.

The efficacy of radiofrequency does not depend on a single factor, but on a combination of several: emission power, depth of penetration, the number of frequencies used and the device's ability to monitor and maintain the optimal working temperature. Not all devices on the market meet these conditions. Those that do are backed by independent laboratory efficacy tests with measurable results.

The first visible results appear after 28 days of regular use. From eight weeks onwards, changes in firmness, elasticity and dermal density are sustained and statistically significant.


Facial device · Full face

TriPollar Aura

The most advanced facial radiofrequency on the market. 6-frequency Multi-RF, DMA muscle activation and red LED 630 nm in a single session of 10 to 12 minutes.

Technology

TriPollar Aura integrates three technologies in simultaneous synergy:

6-frequency Multi-Radiofrequency. While most devices on the market work with one or three frequencies, Aura uses six simultaneously: 0.85 MHz 0.91 MHz 0.97 MHz 1.03 MHz 1.09 MHz 1.15 MHz. This ensures an exhaustive sweep of all dermal layers, maximising collagen and elastin production uniformly. The technology is patented by Pollogen, an Israeli company with over 15 years of experience in professional medical aesthetic technology.

Long-Pulse Dynamic Muscle Activation (DMA). An evolved version of the classic DMA current, with longer pulses that stimulate circulation, contribute to cellular oxygenation and improve firmness from the deep muscle planes.

Red LED at 630 nm. Designed to penetrate the dermal layers and enhance cellular activation after the radiofrequency treatment.

Gold-plated electrodes. Gold is the most efficient thermal conductor available. It allows homogeneous and deep energy delivery, eliminates heat spikes and ensures the device's power translates into real cellular stimulation.

Smart heat at 43 °C. Reaches optimal temperature in just 18 seconds and maintains it constantly. The device monitors skin temperature 1,000 times per second, adjusting energy in real time to guarantee total safety in every session.

Efficacy test results

Independent laboratory SGS · 34 women aged 26 to 53 · Consistent use over 28 to 42 days

+28.59%Density
+30.18%Elasticity
+14.81%Firmness
+31.76%Hydration
−22.10%Forehead wrinkles
−22.15%Nasolabial fold
−21.89%Crow's feet
16 minFlash effect from the 1st session

Independent clinical study SGS. Flash effect demonstrated after a single 16-minute session.

Usage protocol

1
PreparationCleanse and dry your face. Apply a thin layer of the Radiofrequency Preparation Gel to the area to be treated. It is recommended to drink water before the session to optimise thermal conductivity.
2
Power levelStart at level 1. On the neck, lip contour and eyes, always use level 1. Avoid the central neck area (thyroid).
3
RF treatmentGentle, upward circular movements over 5x5 cm areas. Change zone when you hear the beep (every 2 minutes). Total duration: 10 to 12 minutes.
4
RF + DMA modeActivate DMA mode (blue light). Apply only to chin, jaw and cheekbones with circular upward movements for 2 minutes per zone.
5
FinishTurn off the device and remove excess gel. Avoid cooling the skin with cold water immediately after treatment so the residual heat continues to act.
PhaseFrequencyDuration
Initial phase2 to 3 times per week6 to 8 weeks
Maintenance1 to 2 times per weekOngoing
Main contraindications

Not recommended during pregnancy. Contraindicated with pacemakers, active oncological processes, autoimmune diseases and active dermatitis. Do not apply over the thyroid, eyeballs or lips.

Compatible with
Silicone LED Mask: use after TriPollar Aura treatment to enhance cellular regeneration.
TriPollar Envig EDGE: alternate on different days to work surface texture and deep structure in a complementary way.
Facial device · Face and contour

TriPollar STOP Vx2

Next-generation facial radiofrequency. 3-frequency Multi-RF with intelligent thermal mapping algorithm and dynamic muscle activation for deep structural recovery.

Technology

3-frequency Multi-Radiofrequency. The Stop Vx2 works with three multipolar radiofrequency frequencies that act simultaneously on different points of the dermis, reaching up to 41.6 °C. This homogeneous heat distribution activates fibroblasts to initiate neocollagenesis, the creation of new collagen, with a flash effect visible from the first session.

Dynamic Muscle Activation (DMA). DMA currents act on facial musculature through controlled, progressive contractions that strengthen the structural support of the face. Particularly effective along the jawline and cheekbones, where loss of muscle tone becomes most visible over time.

Intelligent thermal mapping algorithm. The integrated sensor monitors tissue temperature in real time throughout the session, automatically adjusting energy. When the tissue reaches the optimal bioestimulation temperature, the device indicates this with an orange light and an audible signal. At that point, the device is kept working on the area for between 30 seconds and 2 minutes, when it is performing at maximum efficiency.

Efficacy test results

Independent clinical evaluation SGS · 33 participants · 28 days of home use · Ultrasound measurements

+31.17%Firmness
+22.18%Elasticity
+24.22%Radiance
+18.91%Dermal thickness
+39.71%Dermal density
97%Participants with perceived improvement

All measurements obtained by ultrasound, evidencing active stimulation of collagen production.

Wrinkle improvement at day 28

AreaMeasured improvement
Crow's feet (length)−30.97%
Crow's feet (area)−29.08%
Crow's feet (volume)−24.85%
Forehead wrinkles−16.67%
Glabellar wrinkles−15.79%
Nasolabial fold−10.93%

Usage protocol

1
PreparationCleanse and dry your face. Apply an even layer of Radiofrequency Preparation Gel to clean, dry skin.
2
RF modeGentle, constant circular movements over 5x5 cm areas. When the orange light comes on, hold on the zone for 1 to 2 minutes. Gradually extend the movement over 3 to 4 minutes per zone.
3
RF + DMA modeActivate the blue light. Linear, slow movements along the jawline for 3 to 4 minutes per side. DMA technology is applied only from the jawline to below the eye. Always use level 1 around the eyes, lips and neck.
4
FinishRemove excess gel with lukewarm water, never cold. Apply your usual skincare routine to maximise absorption.
PhaseFrequencyDuration
Initial phase2 to 3 sessions per week on alternate days6 to 8 weeks
Maintenance1 to 2 sessions per weekOngoing
Main contraindications

Not recommended during pregnancy. Contraindicated with pacemakers, electrical heart problems, diabetes, oncological processes, autoimmune diseases and active acne. Do not apply over the thyroid, eyeballs, lips or nose. After Botox, wait 1 month. With permanent fillers, do not use on that area.

Compatible with
Silicone LED Mask: use after Stop Vx2 to enhance cellular regeneration and amplify collagen synthesis.
Infrared LED Mat: facial radiofrequency session while the mat works on body regeneration simultaneously.
TriPollar POSE Vx: comprehensive firmness and toning protocol for face and body with the same technology.
Body device · Abdomen, thighs, glutes and arms

TriPollar POSE Vx

Body radiofrequency and muscle remodelling. The only home device that acts on dermis, hypodermis and muscle simultaneously with technology patented by Pollogen.

Technology

Multi-Radiofrequency at 1 MHz. Raises dermal temperature in a controlled manner, between 38 °C and 41 °C, the clinically validated temperature for collagen stimulation. Acts simultaneously on the hypodermis, accelerating the metabolism of localised fat and contributing to cellulite reduction. The automatic temperature sensor monitors in real time and stops treatment if the safety threshold is exceeded.

Dynamic Muscle Activation (DMA). Works the underlying muscles through calibrated currents that tone and strengthen deep musculature. By alternating contraction and relaxation, it contributes to lymphatic drainage, eliminates accumulated toxins in the tissues and improves microcirculation. This muscle activation provides a firm base that redefines the contour from within.

Dual customisable mode. Green mode activates only Multi-RF to work on firmness and dermal density. Blue mode combines Multi-RF and DMA simultaneously for comprehensive action on skin and muscle.

Efficacy test results

Independent controlled clinical study · 27 women aged 22 to 43 · 28 days · Blind self-comparison study · 0% adverse effects

−6.20%Waist · 100% improved
−6.18%Upper arm · 100% improved
−4.79%Thighs · 100% improved
−3.60%Calf · 96% improved

Results observed from day 3, increased at day 14, maximum effect at day 28. 100% would continue using the device and would recommend it.

Usage protocol

1
Patch testBefore first use, apply gel to the inner arm and treat the area for a few minutes. Wait 24 hours to verify there is no adverse reaction.
2
PreparationApply a thin, even layer of Radiofrequency Preparation Gel to clean, dry skin. Gel is essential for conductivity: without it, the device does not work correctly.
3
ApplicationDivide the area into 12x12 cm sections. Move the device slowly and steadily at 1 cm per second in circular or figure-eight movements. Slow movements heat the tissue internally. Keep all 4 electrodes in contact with the skin at all times.
4
Optimal temperature signalWhen the orange light comes on and a beep sounds, the device has reached between 38 and 41 °C. Continue with slow circular movements keeping the orange light on as long as possible.
AreaDuration per sessionInitial frequency
Abdomen / thighs / glutes15 to 20 minutes2 to 3 times per week · 8 to 12 weeks
Arms10 minutes per arm2 to 3 times per week · 8 to 12 weeks
Maintenance (all areas)Same1 to 2 times per week
Main contraindications

Do not use on face, neck, ears, chest, genital area or armpits. Not recommended during pregnancy. Consult a doctor if you have medical conditions, high blood pressure or circulatory problems. Not recommended for those under 18. Do not stop moving the device while it is in contact with the skin.

Compatible with
PressTech: use POSE Vx to firm and tone, followed by PressTech to optimise lymphatic drainage and enhance the elimination of toxins released during treatment.
Glo 910 PRO: use Glo 910 PRO before POSE Vx to improve microcirculation and prepare tissue for radiofrequency treatment.
Facial device · Texture, pigmentation and epidermal renewal

TriPollar Envig EDGE

The first fractional radiofrequency device for home use. A3F technology patented by Lumenis, FDA-approved. No gel. No cables. 3 minutes per zone.

Technology

Fractional radiofrequency A3F (Applicator 3 Fractional). A3F technology is patented by Lumenis, the world leader in medical aesthetics, and approved by the FDA. It is the same technology that until now only existed in specialised medical centres, adapted for home use. Unlike conventional radiofrequency, which acts uniformly across the entire surface, fractional technology divides the energy into microbeams that create microscopic thermal columns of 200 to 400 microns in the tissue. This allows treating specific imperfections with clinical precision.

Dual ablative pulse. The first pulse acts on the epidermis, eliminating damaged and dead cells. The second volumetric pulse heats the dermis in depth to stimulate renewal. Both act simultaneously, creating complete renewal in two skin layers at the same time.

Sponge effect. By renewing the epidermis, the skin instantly becomes more permeable, multiplying the efficacy of cosmetics and actives applied afterwards.

Three customisable intensity levels: 64V 70V 76V. Adapted to each user's skin sensitivity and type. Always start at level 1 for the first few weeks.

Wireless and gel-free. The device works directly on the skin using stamping technology. No additional conductors, no cables, no preparation time.

Efficacy test results

Independent study Landproof Labs · 31 subjects aged 21 to 44 · 56-day follow-up

−30%Overall wrinkles · 8 weeks
−85%Forehead wrinkles · 6 weeks
−38%Epidermal pigmentation · 6 weeks
−29%Pore size
+20%Collagen density · 4 months
+37%Texture uniformity · 4 months

Long-term results: −82% forehead wrinkles and −33% pigmentation at 4 months of continued use.

Usage protocol

1
CleansingSkin must be completely clean and dry. Do not apply gels or creams before treatment: the device acts directly on the skin.
2
ApplicationPlace the device on the face, press the button and hold it firmly on the chosen area for a few seconds. A beep indicates the end of the pulse. When you feel the localised heat, lift the device and move to the adjacent area. Repeat across the entire face.
3
IntensityStart at level 1 (64V) for the first weeks. Increase to level 2 (70V) or level 3 (76V) according to tolerance and area. Avoid high intensities on the upper lip and eye area.
4
Post-treatmentIdeal moment to apply cosmetics and actives: the renewal of the outer layer means the skin absorbs them with multiplied efficacy. Sun protection is mandatory for 24 to 48 hours after treatment.
PhaseFrequencyDuration
Renewal cycle2 to 3 times per week8 to 12 weeks
Maintenance1 to 2 sessions per weekOngoing
Main contraindications

Not recommended during pregnancy or for those under 25. Avoid the thyroid area, eye contour and upper lip at high intensities. Sun protection mandatory 24 to 48 hours post-treatment. Discontinue use if irritation, changes in pigmentation or any skin alteration occur and consult a professional.

Compatible with
TriPollar Aura or Stop Vx2: do not use on the same day. On alternate days: Envig EDGE refines the surface while Aura and Stop Vx2 work the deep structure.
Silicone LED Mask: use the LED mask after Envig EDGE to enhance cellular regeneration initiated by fractional radiofrequency and calm the skin during recovery.
Infrared LED Mat: body sessions with the mat complement facial recovery by optimising overall cellular response.

Comparison of all four devices

Each device responds to a specific objective. This table summarises the key differences to help you identify which best suits your needs or how to combine them.

Device Area Main technology Main objective Session duration
TriPollar Aura Face Multi-RF 6 freq. + DMA + LED 630 nm Firmness, density, wrinkles, elasticity 10 to 12 min
TriPollar STOP Vx2 Face and contour Multi-RF 3 freq. + DMA + thermal mapping Deep structure, muscle support, dermal density 15 to 20 min
TriPollar POSE Vx Body Multi-RF 1 MHz + DMA Body firmness, cellulite, contour, muscle 15 to 20 min per area
TriPollar Envig EDGE Face Fractional RF A3F (Lumenis, FDA) Texture, pigmentation, pores, epidermal renewal 3 min

How to combine the devices with your routine

Radiofrequency does not replace cosmetics, it enhances them. Applying actives such as vitamin C, retinol or peptides after a session improves their penetration and efficacy, as the skin is in a state of greater receptivity.

Objective Recommended protocol
Comprehensive facial firmness TriPollar Aura or Stop Vx2 + Silicone LED Mask + active cosmetics
Firmness + facial texture Aura or Stop Vx2 on even days + Envig EDGE on odd days
Body remodelling Glo 910 PRO + POSE Vx + PressTech for posterior drainage
Complete face and body renewal Envig EDGE (face) + Infrared LED Mat (body) in the same session

The recommended usage frequency for all radiofrequency devices is every other day as a minimum. Respecting this interval guarantees the tissue has the necessary time to generate new collagen between sessions.


Frequently asked questions

What is the difference between TriPollar Aura and TriPollar STOP Vx2?

Both are facial devices that combine multi-radiofrequency with DMA technology, but with different specifications. The Aura works with 6 simultaneous frequencies and incorporates red LED at 630 nm, with shorter sessions of 10 to 12 minutes. The Stop Vx2 works with 3 frequencies and reaches up to 41.6 °C thanks to its intelligent thermal mapping algorithm, with a more intensive focus on deep structural recovery and facial muscle toning. They are complementary and can be alternated in the weekly routine.

What does the TriPollar Envig EDGE do if I already have a radiofrequency device?

The Envig EDGE targets a different objective: it does not work on firmness or dermal density, but on the surface quality of the skin. Its fractional radiofrequency technology renews the epidermis, reduces pigmentation, smooths pores and improves texture in a way conventional radiofrequency cannot achieve. They are complementary technologies: while Aura or Stop Vx2 work on the deep structure, Envig EDGE refines the surface. The ideal approach is to alternate them on different days.

Can I use body and facial radiofrequency in the same session?

Yes. The TriPollar POSE Vx for the body and facial devices for the face act on different areas and do not interfere with each other. In fact, combining facial radiofrequency with the Infrared LED Mat in the same session is one of the most comprehensive protocols for working on overall wellbeing simultaneously.

Does the TriPollar Envig EDGE require gel?

No. It is the only device of the four that works directly on dry skin using stamping technology, without the need for a conductive gel. This makes it the fastest and cleanest treatment in the family, with sessions of just 3 minutes per zone.

How often should I use each device to see results?

The recommended frequency for all radiofrequency devices is 2 to 3 sessions per week during the initial phase of 6 to 12 weeks, always allowing at least 24 hours between sessions on the same area. Once the initial phase is complete, move to maintenance of 1 to 2 weekly sessions. The first results are visible after 28 days of regular use.

Do you have questions about which device best suits your routine or skin type?

Write to us at info@skinvity.com or follow us at @skinvity. Our team is here to help.

Discover all SKINVITY radiofrequency devices and find the protocol that suits your objective.

View devices