Instructions for use

Instructions for use, safety information, maintenance, and recommended frequency for SKINVITY devices. Read this information before first use and keep it for as long as you use the device.

Silicone LED Mask

LED phototherapy device for the face, neck, and décolleté. Five wavelengths in the visible and infrared spectrum: red (630 nm), blue (470 nm), and infrared (830 nm, 930 nm, and 1072 nm). Does not use ultraviolet (UV) light.

Technical specifications

  • 650+ LED diodes, strategically distributed across the mask
  • Clinical output of 30 mW/cm²
  • 5 adjustable intensity levels (1 to 5)
  • Ergonomic silicone design with built-in eye protection

Instructions for use

  1. Connect the device and press the ON/OFF button.
  2. Place the mask on clean, dry skin on the face, neck, and décolleté and adjust the strap.
  3. Use the MODE button to select the wavelength or treatment.
  4. Use the LEVEL button to choose the intensity (level 1 to 5).
  5. Session duration: at least 10 minutes. Level 5 is recommended for optimal effect. Maximum of 1 to 3 sessions per day: more than three sessions provides no additional benefit.

Maintenance and cleaning

Clean only with a soft cloth. Do not submerge in water and do not clean with chemical agents.

Recommended frequency of use

Intensive period: 14 sessions, 2 to 3 times per week for 3 to 4 weeks. Maintenance thereafter: 2 to 4 sessions per month.

Safety information and contraindications

  • Suitable from 14 years of age.
  • Pregnancy: not recommended without medical advice.
  • Does not use ultraviolet (UV) light.
  • Possible reactions: mild, temporary redness, swelling, or heat sensation on sensitive skin.
  • Consult a doctor for specific skin conditions or ongoing medical treatments.

Manufacturer and customer service

Manufacturer: Femtechnology S.L., Vía de las dos Castillas 9 C, Bloque 3, Portal 2, 1ºB, 28224 Pozuelo de Alarcón, Madrid, Spain.

Customer service: info@skinvity.com, +34 679 70 34 87.

PressTech

Air pressure-based body device for pressotherapy, with ergonomic pants and 6 overlapping air chambers (groin, abdominal area, and buttocks).

Technical specifications

  • Adjustable pressure: 30 to 260 mmHg
  • 6 programmable compression modes: Normal, Sequential (continuous drainage), Double wave, Full pressure, Dual, and Integral
  • One-size pants (S/M), expandable to size L (42) with the included extension accessory
  • Independent battery: 20 to 30 minutes of autonomy

Instructions for use

  1. Put on the pants and connect all parts.
  2. Switch on the device.
  3. Select the desired duration, pressure, and operating mode.
  4. Start the session.

Maintenance and cleaning

Clean with a damp cloth. Alcohol can be used to remove stains.

Recommended frequency of use

To reduce cellulite: 1 to 2 times per week. As maintenance: 2 to 4 times per month.

Safety information and contraindications

  • Not recommended for persons under 18 years of age.
  • During pregnancy: consult a doctor and never apply pressure to the abdomen.
  • Consult a doctor for specific medical conditions.

Manufacturer and customer service

Manufacturer: Femtechnology S.L., Vía de las dos Castillas 9 C, Bloque 3, Portal 2, 1ºB, 28224 Pozuelo de Alarcón, Madrid, Spain.

Customer service: info@skinvity.com, +34 679 70 34 87.

Infrared LED Mat

Body device for photobiomodulation with more than 3,700 light points in direct contact with the skin. Three wavelengths: 630 nm, 830 nm, and 1072 nm. Classification: aesthetic and wellness device, not a medical device. Works at the cellular level and provides a gentle, comfortable sensation through the interaction between light and tissue, without a sauna effect.

Instructions for use

  1. Place the mat on a flat, dry surface and connect the adapter.
  2. Ensure the skin is clean and completely dry.
  3. Lie on the mat and press the on/off button.
  4. The device will automatically switch off after 20 minutes.
  5. Allow the mat to cool down before storing it.

Maintenance and cleaning

Clean only with a damp cloth.

Recommended frequency of use

20 minutes per session, 2 to 5 times per week. Daily use is possible.

Safety information and contraindications

  • Not recommended during pregnancy or if trying to conceive.
  • Not recommended for pacemaker users.
  • Not recommended for photosensitive conditions or photosensitizing medication.
  • Not recommended for autoimmune diseases, including lupus and porphyria.
  • Not recommended for active cancer conditions or a history of cancer.
  • Not suitable for persons under 16 years of age.
  • Not recommended for skin types V and VI (Fitzpatrick classification).
  • Not recommended after recent surgery or with skin lesions.

Manufacturer and customer service

Manufacturer: Femtechnology S.L., Vía de las dos Castillas 9 C, Bloque 3, Portal 2, 1ºB, 28224 Pozuelo de Alarcón, Madrid, Spain.

Customer service: info@skinvity.com, +34 679 70 34 87.

TriPollar Aura

Radiofrequency device for the face with red LED light (630 nm) and dynamic muscle activation (DMA). Six simultaneous frequencies (0.85 to 1.15 MHz), reaches up to 43 °C with continuous temperature monitoring. Total treatment time: 10 to 12 minutes.

Instructions for use

  1. Preparation: clean and dry the face and apply a thin layer of preparation gel.
  2. Choosing power level: start at level 1 and then move to level 2 or 3. Use level 1 for sensitive areas (neck, lips, eyes). Avoid the thyroid area in the neck.
  3. RF treatment: gentle, circular, upward movements on 5 × 5 cm areas. Change areas at the audible signal. Total duration: 10 to 12 minutes.
  4. Combined treatment (RF and DMA): activate the DMA mode (blue light), only on the chin, jawline, and cheekbones, 2 minutes per area with circular movements.
  5. Finishing: switch off and unplug, wipe the head with a soft cloth and store in a dry place.

Post-treatment care

Remove gel residue with warm water and a soft towel. Follow with a moisturizing serum or cream.

Maintenance and cleaning

Use a soft, slightly damp cloth without alcohol. Never submerge in water. Do not use abrasive products. Store in a cool, dry, and dust-free place.

Recommended frequency of use

Intensive protocol: 2 to 3 times per week for 6 to 8 weeks, with a rest day between sessions. Maintenance thereafter: 1 session per week or 2 to 4 sessions per month.

Safety information and contraindications

  • Areas to avoid: eyes, eyelids, eye bags, lips, nose, and thyroid area.
  • Botox: wait 1 month before applying an RF treatment.
  • Permanent fillers: do not treat those areas.
  • Temporary fillers: treatment is preferably avoided.
  • PDO threads: wait until fully healed.
  • Not recommended during pregnancy or if trying to conceive.
  • Not recommended with an artificial heart valve.
  • Not recommended with electrical heart problems.
  • Not recommended with uncontrolled diabetes.
  • Not recommended with a history of cancer, even in remission.
  • Normal side effects: mild redness or warmth, which usually disappears within a few hours.
  • Dental implants and braces: safe to use. Consult a doctor if there is discomfort.
  • Moles: use is permitted on normal moles. Consult a dermatologist if in doubt.

Manufacturer and customer service

Manufacturer: Lumenis Be, Inc., 1870 South Milestone Drive, Salt Lake City, Utah 84104, United States.

EU Responsible Person: Femtechnology S.L., Vía de las dos Castillas 9 C, Bloque 3, Portal 2, 1ºB, 28224 Pozuelo de Alarcón, Madrid, Spain.

Customer service: info@skinvity.com, +34 679 70 34 87.

TriPollar Stop Vx2

Multipolar radiofrequency and dynamic muscle activation (DMA) for the face. Three frequencies that reach up to 41.6 °C, with a smart sensor for real-time temperature monitoring. Full clinical-level treatment in approximately 15 minutes.

Instructions for use

  • Preparation gel is required for use.
  • Apply to the face and neck. Avoid the windpipe and the thyroid area.

Recommended frequency of use

3 times per week for 6 to 8 weeks. Then 2 to 4 times per month as maintenance.

Safety information and contraindications

  • Not during pregnancy or breastfeeding.
  • Not for persons under 18 years of age.
  • Not with an artificial heart valve.
  • Not recommended with diabetes.
  • Contraindicated with a history of cancer.

Manufacturer and customer service

Manufacturer: Pollogen Ltd., 6 Kaufman St., Gibor House, P.O. Box 50320, 6801298 Tel Aviv, Israel.

EU Responsible Person: Femtechnology S.L., Vía de las dos Castillas 9 C, Bloque 3, Portal 2, 1ºB, 28224 Pozuelo de Alarcón, Madrid, Spain.

Customer service: info@skinvity.com, +34 679 70 34 87.

TriPollar POSE Vx

Body device that combines multi-radiofrequency (1 MHz) with dynamic muscle activation (DMA), for use on the abdomen, arms, buttocks, thighs, hips, and waist.

Instructions for use

  1. Read the manual carefully and ensure you have uninterrupted time.
  2. Apply a thin but generous layer of preparation gel to clean, dry skin.
  3. Connect the device and activate the desired technology: radiofrequency only or combined with DMA. Two power levels are available. Start at the lowest level when using for the first time.
  4. Select the treatment area and ensure all electrodes make contact with the skin. Start with circular movements on a small area.
  5. When the optimal temperature is reached, an audible signal sounds and the orange light comes on.
  6. Gradually increase the diameter and keep the orange light active for about 5 minutes per 12 × 12 cm area.
  7. Clean the device with a dry cloth, remove gel residue, and apply a moisturizing cream.

Automatic temperature sensor

Monitors the temperature in real time and keeps it between 38 °C and 41 °C, the range adjusted for safety and effectiveness.

Recommended treatment areas

Thighs, buttocks, abdomen, hips, waist, and arms.

Recommended frequency of use

3 times per week for 8 to 10 weeks, on alternate days. Then 2 to 4 times per month as maintenance.

Safety information and contraindications

  • Not recommended for persons under 18 years of age.
  • Not recommended for pregnant individuals.
  • Not recommended with an artificial heart valve or electrical heart problems.
  • Not recommended with diabetes, regulated or otherwise.
  • Not recommended with a history of cancer (even in remission), skin cancer, or precancerous moles.
  • Consult a doctor regarding any specific health condition or skin condition prior to use.

Manufacturer and customer service

Manufacturer: Pollogen Ltd., 6 Kaufman St., Gibor House, P.O. Box 50320, 6801298 Tel Aviv, Israel.

EU Responsible Person: Femtechnology S.L., Vía de las dos Castillas 9 C, Bloque 3, Portal 2, 1ºB, 28224 Pozuelo de Alarcón, Madrid, Spain.

Customer service: info@skinvity.com, +34 679 70 34 87.

TriPollar Envig Edge

Fractionated radiofrequency (A3F technology) for the face and neck. Wireless treatment without gel, from 3 to 4 minutes per session.

Technical specifications

  • Three intensity levels: level 1 (64 V), level 2 (70 V), level 3 (76 V)
  • Battery life: approximately 30 minutes, about 6 uses per full charge

Instructions for use

  1. Read the manual carefully.
  2. Ensure the device is charged.
  3. Clean and dry the face.
  4. Divide the face into four zones: both cheeks, forehead, and the area around the mouth.
  5. Switch on and select the power level: level 1 for the area around the eyes, lips, and neck; level 2 or 3 for the rest.
  6. Place against the skin and press the button to release the energy pulse. Ensure overlapping without a double pulse on the same zone.
  7. A full session lasts a maximum of 3 to 4 minutes.
  8. Finish with a soothing and moisturizing product.
  9. Apply sun protection the next day.

Package contents

  • 1 Envig Edge device
  • 1 power adapter
  • User manual
  • 3-year legal warranty (Spain). Outside of Spain, the warranty applies according to the legislation of the country of purchase.

Maintenance and cleaning

Clean the device with a cloth containing 70% alcohol.

Recommended frequency of use

2 to 3 times per week for 6 to 8 weeks. Then 2 to 4 times per month as maintenance. Recommended area: face, including nose, and neck, avoiding the windpipe. Can be extended to the décolleté, but not the breast.

Expected sensation during use: a slight tingling or stinging sensation, followed by a heat sensation comparable to an intensive peel. Start with a low intensity.

Safety information and contraindications

  • Not recommended for allergies, active acne, psoriasis, eczema, or rosacea.
  • Not recommended for open wounds, sunburn, or active skin rashes.
  • Not suitable for persons under 18 years of age.
  • Not recommended during pregnancy.
  • Not recommended if you have an artificial heart valve.
  • Not recommended for electrical heart conditions.
  • Not recommended for diabetes, even if controlled.
  • Not recommended for a history of cancer.
  • Not recommended for extreme skin sensitivity.
  • Consult a dermatologist in case of doubt.

Manufacturer and customer service

Manufacturer: Pollogen Ltd., 6 Kaufman St., Gibor House, P.O. Box 50320, 6801298 Tel Aviv, Israel.

EU Responsible Person: Femtechnology S.L., Vía de las dos Castillas 9 C, Bloque 3, Portal 2, 1ºB, 28224 Pozuelo de Alarcón, Madrid, Spain.

Customer service: info@skinvity.com, +34 679 70 34 87.

This page contains usage instructions, safety information, maintenance, and recommended frequency. In case of doubt or a specific medical condition, always consult a doctor or dermatologist before use. Questions: info@skinvity.com.